Q&A With Sridhar Iyengar, Founder and Chief Strategy & Technology Officer
Did Hackers Really Take Over Freezers?
Yes. This fall, attackers took remote control of commercial refrigeration systems in Europe and the United States.
Most of the targets were supermarkets. In October, several hundred stores in France lost frozen and refrigerated food in a single night. In early November, stores in at least nine more European countries were hit. In the United States, the Department of Defense is investigating freezer failures at six military base grocery stores as a possible cyberattack.
Then, on November 1, the attacks reached the life sciences.
What Happened at the French Blood Service?
Cold rooms at three sites of the French national blood service (EFS) were affected. These rooms hold plasma and biobank samples, normally stored at about -25° C. The temperature settings were reportedly changed to 110° C.
EFS staff saw the alarms, responded quickly, and moved the plasma.
No blood products were lost. No samples were affected.
That outcome is the most useful part of the story, and we come back to it below.
How Did the Attacks Work?
Nothing was broken into in the usual sense. The attackers logged in to refrigeration controllers that were connected to the internet. Then they used ordinary functions, like the defrost cycle and the temperature settings, to warm the equipment up.
Many of these controllers were older models with a built-in web interface that let technicians view performance and change settings. They were designed for use on a local network. Many were later connected to the internet so that contractors could monitor and service equipment remotely, often without strong security, and the oldest models no longer received security updates.
In the EFS case, the blood service wasn’t the direct target. The attackers reached the systems its refrigeration supplier uses to manage the cold rooms.
No one has claimed responsibility, and investigations are ongoing.
Should Labs Be Concerned?
Labs often rely on the same kinds of equipment: ultra-low temperature freezers, refrigerators, incubators, and cold rooms. More of it is connected every year, and many service contracts include remote access for the manufacturer or a service provider.
That connectivity has real benefits. It’s also worth knowing where risk exists.
The risk is highest where equipment is controlled through the internet. If a freezer or instrument can be controlled remotely, through its own network connection or through a vendor’s cloud service, that connection is a path an attacker can use.
There’s also a risk many labs may not have considered: smart plugs and other devices that sit in line with an instrument’s power. Labs use them to monitor power or equipment use, and some are consumer-grade products rather than industrial-grade ones. A hacked smart plug can’t change a freezer’s settings, but it can switch the freezer off or switch it off and on again. Any networked device in the power line deserves the same scrutiny as the equipment controller itself.
Two lessons stand out:
- Know which connections can change your equipment’s settings. That includes connections you don’t manage yourself, such as a service provider’s remote access.
- Monitor critical equipment independently. If someone can change a controller’s temperature settings, they may also be able to change its alarm limits, if monitoring and control are the same system. A monitoring system that works separately from the equipment keeps measuring the real temperature, and its alarm limits can’t be altered through the equipment.
How Does Elemental Machines Fit In?
Many of our customers have asked how these events relate to their Elemental Machines systems. Here’s how our system is designed:
- We monitor; we don’t control. Element-T measures temperature with its own probe, Element-A measures conditions in the room, and Element-U measures how equipment is used from outside the power cord; these are independent sensors, meaning that they take their own measurements and are not connected to any control path in your instrument
- Integrated, but designed for reading. Element-C, Element-D, and Element-B connect directly to instruments to collect their data; like all of our systems, they are designed to read data, not to control instruments, and they are not configured for any control
- Built to read, not to control. Our devices (Gateways and Elements) send your data outbound to the Elemental Machines cloud over secure connections; they are designed to read data from your instruments and they have no built-in web interface for changing settings
- Updates handled for you. When a security issue is identified, we update the firmware on our devices ourselves, over the same secure connections to our cloud; you don’t need to do anything
- Nothing in the power line. Element-U is the only utilization sensor that is completely noninvasive. It clips onto the outside of the power cord and senses the magnetic field around it. It has no electrical contact with the power supply and no switch. Smart plugs work differently: They sit between the outlet and the instrument, so a compromised smart plug could turn an instrument off or on. Element-U has no way to do that. So, if you want to measure equipment utilization or energy consumption, Element-U gives you that information without placing a networked switch between your instrument and its power supply
- An independent view of your equipment. Our readings and alerts travel through the Elemental Machines gateway and cloud, not through your instrument’s controller; if a freezer’s settings were ever changed remotely, our sensor would still measure the real temperature and alert your team when it moved outside the range you set
Remember the blood service? What protected its plasma was a fast alarm and a fast response. Independent monitoring is built to give you that alarm, even when the equipment itself has been told something different.
What Can Your Lab Do Today?
Security agencies, equipment manufacturers, and security researchers have shared guidance since these events, including a joint advisory from CISA, the FBI, and three other U.S. agencies on November 5, 2026. For labs, here are the practical steps:
- List the equipment, controllers, and in-line power devices, such as smart plugs, that are connected to a network. Include any remote access held by a manufacturer or service provider.
- Work with your IT team to strengthen your firewalls and control how equipment connects to the internet. Where remote service access is needed, use a secure, controlled connection.
- Ask your equipment suppliers and service providers to confirm that the latest firmware and security patches are installed, and change any default passwords. Plan to replace controllers that no longer receive security updates.
- Monitor your most critical equipment with sensors that are independent of the equipment controller.
- Review your alert setup. Check that alert thresholds are set properly, that notifications by text message, voice call, or email are configured correctly, that the right people are on the recipient list, and that escalations are set up correctly. Make sure someone covers alerts at night and on weekends.
- Look through your historical alert logs and confirm that your staff are responding to alerts properly.
- Have a backup plan. Know where product would go, and how quickly it could be moved, if a freezer or cold room failed.
None of these steps are complicated. Together, they make a real difference.
Frequently Asked Questions
Our systems are designed to read data, not to control instruments. Element-T, Element-A, and Element-U are not connected to your instrument’s controls at all. Element-C, Element-D, and Element-B connect to instruments only to collect data, and our devices send data outbound to our cloud over secure connections.
No. Element-U clips onto the outside of the power cord. It has no electrical contact with the power supply and no switch.
Yes. Element-U measures equipment utilization and energy consumption from outside the power cord. Because it has no electrical contact with the power supply and no switch, it adds no new way for your instrument to be turned off.
Our sensors measure actual conditions independently of your equipment’s controller. If a freezer’s temperature moved outside the range you set, for any reason, your team would be alerted.
We’d recommend a risk-based approach. Disconnecting everything from the internet gives the highest level of security, but it also gives up real benefits, such as remote support from your service providers and remote visibility for your team. For most labs, the better path is stronger firewalls, current firmware and security patches, and secure remote access. No system is completely risk-free, so the most important step is independent monitoring, with staff trained to respond to its alerts.
Start with your service contracts and your equipment vendors. Your IT or facilities team can help confirm how each instrument is connected.
References
- TNW. “Cyberattack pushed French blood bank freezers to extreme temperatures.” November 4, 2026.
- TechRadar. “Hackers target French blood banks in latest freezer attack, as UK cybersecurity chief warns of ‘sliding doors’ moment for ‘unprecedented’ threat.” November 4, 2026.
- The Hacker News. “Attackers Heat French Supermarket Fridges Up to 50°C by Hijacking Danfoss Controllers.” October 13, 2026.
- The Hacker News. “New Wave of Refrigeration Cyberattacks Hits Supermarkets Across Europe, Forcing Stores to Pull Food.” November 3, 2026.
- Nextgov/FCW via Defense One. “Pentagon investigates suspected cyberattack behind military freezer failures.” October 29, 2026.
- Help Net Security. “US agencies warn attackers are targeting refrigeration systems that protect food and medicine.” November 6, 2026.
Have questions about your Elemental Machines system? Talk with our team or reach out to your customer success manager. We’re happy to review your alert settings with you.